Canadian Electrical Installation Standards (CEIS) Store
Catalogue Overview
The Canadian Electrical Installation Standards™ (CEIS™) have been adopted from the National Electrical Contractors Association (NECA) National Electrical Installation Standards™ (NEIS™) in the United States. These NEIS™ have been reviewed by a Canadian technical committee assembled to Canadianize the standards by referencing the requirements of CSA C22.1, Canadian Electrical Code, Part I (CEC, Part I), published by CSA Group, and the methods used for electrical installations across Canada and to find opportunities to harmonize with the United States, where possible.

CEIS™ are intended to improve communication and consistency among designers, engineers, general contractors, specifiers, purchasers, and suppliers of electrical construction services. They define a minimum baseline of quality and workmanship for installing electrical products and systems. CEIS™ are intended to be referenced in contract documents for electrical construction projects.

After you have selected the publications you want to order, scroll to the bottom of the page and select the "Proceed" button to complete your purchase.
Available for Purchase
CEIS Licensing Agreement
more info

CECA is introducing a new Canadian Electrical Installation Standards (CEIS) offering. 


Along with the hardcopy and PDF download versions of the CEIS documents, CECA is now offering a license agreement offering that will allow our contractor members to update their company work instruction manuals with wording and images from the CEIS documents.


Companies can now include the entire contents or select sections from the CEIS documents within their existing company documents. This will be a time saving solution and ensure staff always have access to the standards without having to buy multiple copies for each active work project. 


License agreements are customized to the needs of the contractor and pricing is based on the contractor requirements. 


Please contact CECA to discuss pricing.


416-491-2414


Member Price
more info
$0.00
Complete Set of 35 Standards Books
more info
Save money by purchasing a complete set of standards. Half the price of purchasing individual books.

The complete set of books come in a set of protective binders with descriptive inserts.
Member Price
more info
$550.00
Non Member Price
more info
$700.00
Complete Set of 35 Standards Digital Downloads
more info
Save money by purchasing a complete set of standards. Half the price of purchasing individual books.

The complete set of PDF's come on a USB flash drive. If you prefer, contact ceca and ask to have your PDF's made available for download instead.
Member Price
more info
$550.00
Non Member Price
more info
$700.00
CECA 1 Good Workmanship in Electrical Construction Book
more info
This standard describes what is meant by "quality of work" as required for electrical installations by Canadian Standards Association (CSA) C22.1, Canadian Electrical Code, Part I (CEC, Part I), Rule 2-108.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 1 Good Workmanship in Electrical Construction Digital Download
more info
Digital PDF version of the above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 100 Standard for Symbols for Electrical Construction Drawings Book
more info
This standard describes symbols commonly and primarily used to represent electrical wiring and equipment on electrical construction drawings. Related symbols are organized into different groups, and each symbol within a group has its own identifying number. The group and symbol numbers are not significant except as a convenient way to identify individual symbols. See Table 1 for groups. This standard also summarizes recommended drawing practices for electrical construction drawings.
Member Price
more info
$60.00
Non Member Price
more info
$90.00
CECA 100 Standard for Symbols for Electrical Construction Drawings Digital Download
more info
Digital PDF version of the above publication.
Member Price
more info
$60.00
Non Member Price
more info
$90.00
CECA 90 Standard for Commissioning Building Electrical Systems Book
more info
This standard describes procedures for commissioning newly installed or retrofitted building electrical systems. It defines the process of commissioning building electrical systems and provides sample guidelines for attaining optimum system performances that conform to design, specifications, and industry‑accepted codes, standards, customer specifications, and standards.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 90 Standard for Commissioning Building Electrical Systems Digital Download
more info
Digital PDF version of the above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 101 Standard for Installing Steel Conduit (Rigid and EMT) Book
more info
This standard describes installation procedures for steel rigid metal conduit (RMC) and steel electrical metallic tubing (EMT). Conduit with supplementary PVC coating (i.e., Robroy®) is also covered.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 101 Standard for Installing Steel Conduit (Rigid and EMT) Digital Download
more info
Digital PDF version of the above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 102 Standard for Installing Aluminum Rigid Metal Conduit Book
more info
This standard describes installation procedures for aluminum rigid metal conduit (RMC), including aluminum RMC with a supplementary PVC coating.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 102 Standard for Installing Aluminum Rigid Metal Conduit Digital Download
more info
Digital PDF version of above publication
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 104 Standard for Installing Aluminum Building Wire and Cable Book
more info
This standard describes installation procedures and design considerations for aluminum building wire and cable in residential, commercial, institutional, and industrial applications not exceeding 600V.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 104 Standard for Installing Aluminum Building Wire and Cable Digital Download
more info
Digital PDF of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 105 Standard for Installing Metal Cable Tray Systems Book
more info
This standard addresses shipping, handling, storage, and installation of cable tray systems. Information on maintenance and system modification is also provided.
NOTE: This standard does not cover all details or variations in cable tray systems nor provide for every possible installation contingency.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 105 Standard for Installing Metal Cable Tray Systems Book Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 120 Standard for Installing Armoured Cable (Type AC) and Metal-Sheathed Cable Book
more info
This standard covers the installation of armoured cable (Type AC) and metalsheathed cables, which are used for electrical wiring in residential, commercial, and industrial occupancies. It also includes information on fittings and other accessories necessary for installation of these cable systems.
Metal-sheathed cables include Types RA90 aluminum- and RC90 coppersheathed cables (see CSA Standard C22.2 No. 123) and mineral-insulated (Type MI) cable. These cables consist of a seamless, smooth metal sheath or a seamed or seamless, corrugated metal sheath applied over one or more insulated conductors. In some cases, an optional non-metallic overall covering is applied over the sheath.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 120 Standard for Installing Armoured Cable (Type AC) and Metal-Sheathed Cable Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 130 Standard for Installing and Maintaining Wiring Devices Book
more info
This standard describes the installation and maintenance procedures for wiring devices.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 130 Standard for Installing and Maintaining Wiring Devices Book Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 169 Standard for Installing and Maintaining Arc Fault Circuit Interrupters (AFCIs) and Ground Fault Circuit Interrupters (GFCIs) Book
more info
This standard describes the installation and maintenance procedures for arc fault circuit interrupters (AFCIs) and ground fault circuit interrupters (GFCIs).
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 169 Standard for Installing and Maintaining Arc Fault Circuit Interrupters (AFCIs) and Ground Fault Circuit Interrupters (GFCIs) Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 200 Standard for Installing and Maintaining Temporary Electrical Power at Construction Sites Book
more info
This standard describes temporary electrical power and lighting systems at construction sites, operating at 600 V or less. It covers the planning, installation, expansion, maintenance, cutover, and removal of the temporary power system. This standard is intended to ensure a safe, adequate, functional, and reliable temporary electrical power system for all trades on site.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 200 Standard for Installing and Maintaining Temporary Electrical Power at Construction Sites Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 230 Standard for Selecting, Installing, and Maintaining Electric Motors and Motor Controllers Book
more info
This standard describes procedures for selecting and installing stationary electric motors and motor controllers rated 750 V or less. The standard also covers routine maintenance procedures for electric motors and motor controllers, to be followed after the installation is complete.
NOTE: For brevity, the term "motor" is used throughout this standard and should be understood to refer to electric motors. All Rule and Table references in this standard refer to the Canadian Electrical Code, Part I (CEC, Part I), unless otherwise noted.
For additional guidance and sample calculations related to motor installations, see C22.1HB, CE Code Handbook, Section 28.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 230 Standard for Selecting, Installing, and Maintaining Electric Motors and Motor Controllers Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 301 Standard for Installing and Testing Fiber Optic Cables Book
more info
This standard describes procedures for installing and testing cabling networks that use fiber optic cables and related components to carry signals for communications, security, control, and similar purposes. It defines a minimum level of quality for fiber optic cable installations.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 301 Standard for Installing and Testing Fiber Optic Cables Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 331 Standard for Building and Service Entrance Grounding Book
more info
This standard describes installation procedures for building and service entrance grounding as well as building interior bonding and grounding. It is intended to define what is meant by acceptable mechanical arrangement and execution of work in electrical installations as required by the CEC, Part I, Rule 2-108.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 331 Standard for Building and Service Entrance Grounding Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 400 Standard for Installing and Maintaining Switchboards Book
more info
This standard describes installation procedures for dead-front distribution switchboards rated 600 V or less.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 400 Standard for Installing and Maintaining Switchboards Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 402 Standard for Installing and Maintaining Motor Control Centres Book
more info
This standard describes installation procedures for motor control centres rated 600 V or less. It also covers periodic routine maintenance procedures for motor control centres and special procedures to be used after adverse circumstances, such as short-circuit, ground fault, or exposure to water.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 402 Standard for Installing and Maintaining Motor Control Centres Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 404 Standard for Installing Generator Sets Book
more info
This standard describes installation procedures for generator sets for on-site power generation.
NOTE: The standard does not cover general design considerations for on-site power systems.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 404 Standard for Installing Generator Sets Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 406 Standard for Installing Residential Generator Sets Book
more info
This standard describes installation procedures for the following:
a) Generator sets permanently installed at single dwellings to provide backup power. These are usually rated 120/240 V, single-phase, 3-wire. However, some large homes have 3-phase electrical systems and use backup generators rated 120/208 V, 3-phase, 4-wire.
b) Generator sets fuelled by gasoline, natural gas, or liquified petroleum (LP) gas.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 406 Standard for Installing Residential Generator Sets Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 407 Standard for Installing and Maintaining Panelboards Book
more info
This standard describes installation and maintenance procedures for panelboards, as well as special procedures to be used after adverse operating conditions such as short-circuits, ground faults, or immersion in water.
This standard applies to panelboards rated 600 V ac or less, with main disconnects or lugs rated 1600 A or less and with feeder or branch circuit overcurrent devices rated 1200 A or less.
This standard applies to single panelboards, multi-section panelboards, and load centres used for distributing power for commercial, institutional, and industrial loads in non-hazardous locations both indoors and outdoors.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 407 Standard for Installing and Maintaining Panelboards Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 408 Standard for Installing and Maintaining Busways Book
more info
This standard describes the installation and maintenance procedures for feeder and plug-in busways and accessories rated 750 V ac or less and 100 A or more. It also covers periodic routine maintenance procedures for busways and special procedures used after adverse operating conditions such as short-circuit, ground fault, or immersion in water.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 408 Standard for Installing and Maintaining Busways Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 409 Standard for Installing and Maintaining Dry-Type Transformers Book
more info
This standard describes the installation and maintenance procedures for single and 3‑phase general‑purpose dry‑type distribution and power transformers and associated accessories rated 750 V ac or less and 0.25 kVA or more.
This standard applies to indoor and outdoor, ventilated and non‑ventilated, single‑phase and 3‑phase transformers used for supplying power, heating, and lighting loads for commercial, institutional, and industrial use in non‑hazardous locations both indoors and outdoors.
It also covers periodic routine maintenance and troubleshooting procedures for transformers and special procedures for use after adverse operating conditions such as a short‑circuit, ground fault, or immersion in water.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 409 Standard for Installing and Maintaining Dry-Type Transformers Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 410 Standard for Installing and Maintaining Liquid Filled Transformers Book
more info
This standard describes installation procedures for pad‑mounted, sealed, self‑cooled, compartmental, single‑ and 3‑phase liquid‑filled distribution and power transformers with primary windings rated from 2400 V to 35 kV ac, nominal, and associated accessories, designed for outdoor installation at grade level with underground entrance of primary and secondary conductors, and used for supplying power, heating, and lighting loads for commercial, institutional, and industrial use in non‑hazardous locations.
It also covers periodic routine maintenance procedures for transformers and special procedures for use after adverse operating conditions, such as a short‑circuit, ground fault, or immersion in water.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 410 Standard for Installing and Maintaining Liquid Filled Transformers Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 411 Standard for Installing and Maintaining Uninterruptible Power Supplies (UPS) Book
more info
This standard describes installation and maintenance procedures for permanently installed, static, three-phase uninterruptible power supplies (UPS) rated 30 kVA or more, and 600 V or less, and related battery systems, installed indoors and outdoors for commercial, institutional, and industrial applications.
UPS described in this standard are solid-state power systems that provide continuous regulated ac power at the output terminals, while operating from either an ac power source or from a battery system.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 411 Standard for Installing and Maintaining Uninterruptible Power Supplies (UPS) Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 412 Standard for Installing and Maintaining Solar Photovoltaic (PV) Power Systems Book
more info
This standard describes the procedures for installing and maintaining solar photovoltaic (PV) power systems and components.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 412 Standard for Installing and Maintaining Solar Photovoltaic (PV) Power Systems Digital Download
more info
Digital PDF of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 420 Standard for Fuse Applications Book
more info
This standard describes application and installation practices and procedures for low-voltage and high-voltage fuses.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 420 Standard for Fuse Applications Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 430 Standard for Installing High-Voltage Metal-Clad Switchgear Book
more info
This standard describes procedures for installing high-voltage metal-clad switchgear for electrical services and power distribution in excess of 750 V ac in non-hazardous locations both indoors and outdoors. It also covers procedures for periodic routine maintenance of high-voltage metal- clad switchgear systems.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 430 Standard for Installing High-Voltage Metal-Clad Switchgear Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 500 Standard for Installing Indoor Commercial Lighting Systems Book
more info
This standard describes installation procedures for lighting systems commonly used in commercial and retail buildings, including but not limited to the following:
a) recessed lighting systems such as troffers, downlights, wallwashers, valance lights, and accent lights
b) ceiling surface-mounted lighting systems such as surface troffers, wraparounds, surface downlights, monopoints, and decorative fixtures
c) ceiling-suspended lighting systems such as pendant luminaires, warehouse or industrial luminaires, uplight systems, or decorative luminaires
d) wall-mounted lighting systems such as sconces or wallpacks
e) track lighting systems.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 500 Standard for Installing Indoor Commercial Lighting Systems Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 501 Standard for Installing Exterior Lighting Systems Book
more info
This standard describes installation procedures for lighting systems commonly used in outdoor applications on and near commercial, institutional, industrial, and storage buildings, including but not limited to the following:
a) pole-mounted spotlights, area lights, sports lights, and floodlights
b) illuminated bollards
c) wall-mounted sconces, wall bracket lights, and wall pack lights
d) above-ground mounted floodlights and spotlights
e) in-ground floodlights and spotlights
f) step lights and other lights recessed into exterior walls and other concrete surfaces
g) canopy and soffit mounted surface lights
h) landscape lighting.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 501 Standard for Installing Exterior Lighting Systems Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 502 Standard for lnstalling Industrial Lighting Systems Book
more info
This standard describes installation procedures for lighting systems commonly used in industrial and storage buildings, including, but not limited to, the following:
a) high-intensity discharge (HID) low-bay and high-bay lighting systems
b) fluorescent strip lights and general-purpose industrial overhead lighting systems
c) common special-purpose and special-environment industrial luminaires
d) lighting installed on industrial wireway and lighting track systems.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 502 Standard for lnstalling Industrial Lighting Systems Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 503 Standard for Installing Fiber Optic Lighting Systems Book
more info
This standard describes installation procedures for glass fiber optic lighting systems.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 503 Standard for Installing Fiber Optic Lighting Systems Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 505 Standard for Installing and Maintaining High Mast, Roadway, Area, and Sports Lighting Book
more info
This standard describes installation and maintenance procedures for high mast, roadway, area, and sports lighting systems installed outdoors for commercial, institutional, and industrial applications. This standard applies to high-intensity discharge (HID) luminaires rated 600 V and less and mounted on poles. This standard does not apply to installations governed by special environmental or regulatory requirements.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 505 Standard for Installing and Maintaining High Mast, Roadway, Area, and Sports Lighting Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 568 Standard for Installing Commercial Building Telecommunications Cabling Book
more info
This standard describes minimum requirements and procedures for installing the infrastructure for telecommunications, including balanced twisted‑pair copper cabling and optical fiber cabling that transport telecommunications signals (e.g., voice, data, video). A structured cabling system is a complete collective configuration of cabling and associated hardware on a premises that, when installed, provides a comprehensive telecommunications infrastructure. This infrastructure is intended to support a wide range of telecommunications services, such as telephone and computer networks. Figure 1 illustrates an example of components that make up a structured cabling system.
This Standard is intended to be used:
a) as a reference for installation of telecommunications cabling in commercial buildings that is acceptable as defined in Section 0 of the Canadian Electrical Code, Part I.
b) in conjunction with all applicable local code requirements. Code requirements are generally included in scope of work documents, but because installers are fully responsible for all work done, it is essential that they familiarize themselves directly with all applicable codes and regulations.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 568 Standard for Installing Commercial Building Telecommunications Cabling Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 600 Standard for Installing and Maintaining High-Voltage Cables Book
more info
This standard describes installation procedures for shielded and non-shielded solid-dielectric high-voltage cables rated in excess of 750 V and installed in conduits and ducts or direct buried. This standard applies to single- and multiconductor cables used for distributing power for commercial, institutional, and industrial loads in nonhazardous locations both indoors and outdoors. These cables are subject to the requirements of Section 36 of the CEC, Part I.
The standard also covers periodic routine maintenance and troubleshooting procedures for high-voltage cable and special procedures to be used after adverse operating conditions such as a short-circuit or ground fault.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 600 Standard for Installing and Maintaining High-Voltage Cables Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 605 Standard for Installing Underground Non-metallic Utility Duct Book
more info
This standard covers procedures for shipping, handling, storage, installation, and joining of underground single-bore, non-metallic duct for power, lighting, signalling, and communications applications.
This standard is not intended to assume or replace any responsibilities of engineers, customer representatives, owners, or other persons in establishing engineering design practices and procedures best suited to individual job conditions.
Although not specifically mentioned in this standard, variations of the products discussed may occasionally be specified. Users should follow the manufacturer's installation recommendations.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 605 Standard for Installing Underground Non-metallic Utility Duct Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 700 Standard for Installing Overcurrent Protection to Achieve Selective Coordination Book
more info
This standard provides an overview of procedures for installing low-voltage overcurrent protective devices to achieve selective coordination based on the available fault current within an electrical distribution system, the ratings and settings of overcurrent protective devices, and system design parameters.
The purpose of this standard is to provide practical design and installation guidance that will meet the requirements of the Canadian Electrical Code, Part I (CEC, Part I) for coordination of overcurrent protective devices.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
CECA 700 Standard for Installing Overcurrent Protection to Achieve Selective Coordination Digital Download
more info
Digital PDF version of above publication.
Member Price
more info
$32.00
Non Member Price
more info
$40.00
Time out warning
The quantity you have selected for your registration will be released back into inventory if you do not restart the timer. Click 'Renew' to reset the timer and give you more time to complete your registration.
Timer Expired
The timer reserving your items has expired, the items have been returned to inventory. You can try to purchase your items again.
Inventory Sold Out
Sorry during the processing of your request the inventory sold out.
More Info
Gregg Whitty